Perform the following operations to verify that VMware NMP configurations have taken effect: After configuring host parameters, restart the host for the configuration to take effect.
Host parameter configuration: Log in to each ESXi host using vSphere Client or vCenter and complete the following advanced settings. After configuring cluster parameters, re-enable HA for the configuration to take effect. Cluster parameter configuration: Use vSphere Web Client to connect to vCenter, go to the cluster HA configuration page, and select Turn on vSphere HA. For VMware vSphere 5.5 and its update versions:.
Host parameter configuration: Log in to each ESXi host using SSH and add Disk.terminateVMOnPDLDefault = True to the /etc/vmware/settings file. In the advanced settings, set das.maskCleanShutdownEnabled = True. Cluster parameter configuration: Use the vSphere Client to log in to each ESXi host. For VMware vSphere 5.0 u1, later 5.0 versions, and vSphere 5.1:. A VM service network requires L2 interworking between data centers so that VM migration between data centers will not affect VM services. The following configurations are mandatory when you configure a VMware cluster: You only need to enable HA again in vCenter for the settings to take effect. Retain the default host parameter settings. Set Datastore with APD to Power off and restart VMs - Aggressive restart policy. Set Datastore with PDL to Power off and restart VMs. =False (Retain the default value.)ĭisk.AutoremoveOnPDL=1 (Retain the default value.) Storage PDL responses may not trigger path failover in VMware vSphere 6.0 GA and 6.0 U1.
esxcli iscsi adapter param set -A vmhba35 -k NoopOutInterval -v 1Įsxcli iscsi adapter param set -A vmhba35 -k NoopOutTimeout -v 10Įsxcli iscsi adapter param set -A vmhba35 -k RecoveryTimeout -v 1 esxcli iscsi adapter param get -A vmhba35 | egrep 'NoopOutInterval|NoopOutTimeout|RecoveryTimeout'
Query the current timeout parameter settings. In the command output, the iSCSI adapter name is vmhba35. Vmhba35 iscsi_vmk online :esxi16113-xxxxxxxxxSCSI Software Adapte Exercise caution when performing this operation.
You must restart the host for the configuration to take effect. įC networking does not require setting of timeout parameters.įor iSCSI networking, perform the following operations on ESXi hosts. For details about the parameters in the host commands, see.New SATP rules will immediately take effect for newly mapped LUNs, but will not take effect for previously mapped LUNs until the host is restarted.In the command, HUAWEI is the storage vendor and XSG1 is the storage model.